Load Cell Simulator LCS-3
|
- High quality load cell simulator with 0.03% accuracy
- In 0.5 mV/V steps from 0 to ± 3 mV/V, continuously variable ± 2mV/V
- Compact pocket size, ideal for service applications
- Input and output impedance 350 Ohm ± 1 Ohm
- Selectable polarity for symmetry tests
- Standardized Dimensions L70 x W29 x H172 mm
|
|
|

|
Load Cell Junction Box QLJ
|
- High quality junction box for up to 4 load cells
- Robust PCB with screw and solder terminals
- Industrial standard aluminium housing
- Cable entries via metal glands
- Sealed to IP 65
- Standard dimensions W175 x H80 x D57 mm
|
|
|

|
Converter USB to RS485/422
|
- Isolated RS485/422 interface
- UK designed and manufactured
- Baud rates up to 1 Mbps
- RS485 half duplex link selectable
- Selectable 120 Ohm termination resistor
- Powered from the USB port
|
|
|

|
Stainless Steel Load Cell Junction Box AJB04-S
|
- Connect up to 4 load cells into one output
- Stainless steel enclosure
- Five stainless steel PG 9 glands
- Sealed to IP67
- Screw terminal connectors for inputs and outputs
- Integrated surge protection
- Easy corner trimming using built-in potentiometers
- Also available for 6, 8, & 10 load cell inputs
|
|
|

|
ATEX Load Cell Junction Box KAEX
|
- Connect up to four load cells into one output
- Aluminium enclosure with earth connection
- Four M16 (Inputs) and one M20 (Output) glands
- Sealed to IP66
- Cascade boxes together for more than 4 load cells
- Screw terminal connectors for inputs and outputs
- ATEX approved EEX ia II C T6
- Add optional resistors for corner error correction
|
|
|

|
Beka Text Display BA688C
|
- Remote serial text display to be used with DAS72.1
- Connects directly to DAS72.1 Communication port
- Internal script requests information from DAS72.1
- Display shows Gross / Net weight & No motion
- Push buttons to set a new zero or tare
- Supply voltage 20 - 36 VDC
- RS 485 2 wire Computer Interface
- Can be used with Wireless Links
|
|
|

|
Beka Text Display BA488C (ATEX Option)
|
- Remote serial text display to be used with DAS72.1
- Can be mounted in the Hazardous area
- Connects to DAS72.1 RS485 port via an comms Isolator
- Internal script requests information from DAS72.1
- Display shows Gross / Net weight & No motion
- Push buttons to set a new zero or tare
- Supply voltage 20 - 36 VDC
- RS 485 2 wire Computer Interface
- Can be used with Wireless Links
|
|
|

|
Safety Barriers for ATEX Applications
|
- For use with load cells working in Hazardous Areas
- Designed to live in the Safe Area
- Limits energy available in the Hazardous Area
- Plug in screw terminal connections
- Din rail clip mounting
- Short circuit protected Zener Barrier
- Compact space saving construction
|
|