Load Cell 1002
Capacities: 0.5, 1, 2, 3, 5, 8,15, 20 kg
|
- Ultra compact, very inexpensive and easy to use Load Cell
- Available in capacities from 0.5 - 20 kg
- Suitable for platform sizes up to 200 x 200 mm
- Ideal for industrial and medical applications
- Constructed from high strength aluminium alloy
- Sealed to IP 66 with a special silicon coating
- Optional 1000 ohm input impedance available
|
|
|

|
Load Cell 1004
Capacities: 0.3, 0.6, 1.5, 3 kg
|
- Load Cell with very good linearity and reproducibility
- Available in capacities from 0.3 - 3kg
- Short term resolutions up to 30,000d and more possible
- Suitable for platform sizes up to 200 x 200 mm
- Ideal for pharmaceutical / medical applications
- Sealed to IP 66 with special coating
|
|
|

|
Load Cell 1006
Capacities: 2, 3, 5 kg
|
- Compact, accurate, easy to use and inexpensive Load Cell
- Available in capacities from 2 - 5 kg
- Suitable for platform sizes up to 200 x 200 mm
- Ideal for industrial and medical applications
- Constructed from high-strength aluminium alloy
- Sealed to IP 66 with a special coating
- Applications in Postal, Counting and General Purpose Scales
- Load Cell with very compact and rugged design
|
|
|

|
Load Cell 1015
Capacities: 3, 5, 7, 10, 15, 20, 30, 50 and 90 kg
|
- Load Cell is available in capacities from 3 - 90 kg
- Suitable for platform sizes up to 350 x 350 mm
- Constructed from high strength aluminium alloy
- Triple beam system with high natural frequency
- Optional ATEX version available approved to II 2G EEx ia IIC T4
|
|
|

|
Load Cell 1022
Capacities: 3, 5, 7, 10, 15, 20, 30, 35, 50, 100, 150 and 200 kg
|
- Available in capacities from 3 - 200 kg
- Maximum height 22 mm
- Load Cell is suitable for platform sizes up to 350 x 350 mm
- Constructed from high strength aluminium alloy
- Approved to OIML R60 up to 4000d
- Dual beam system with high natural frequency
- Optional ATEX version available approved to II 2G EEx ia IIC T4
|
|
|

|
Load Cell 1040
Capacities: 5, 7, 10, 15, 20, 30, 50, 75 and 100 kg
|
- Available in capacities from 5 - 100 kg
- Suitable for platform sizes up to 400 x 400 mm
- Constructed from a high strength aluminium alloy
- Approved to OIML R60 3000D
- Triple beam design with high natural frequency
- Optional Sylgard protection for improved sealing
- Optional ATEX II 2G EEx ia IIC T4 approval available
|
|
|

|
Load Cell 1042
Capacities: 1, 3, 5, 7, 10, 15, 20, 30, 50, 75, 100, 150 and 250 kg
|
- Available in capacities from 1 - 250 kg
- Suitable for platform sizes up to 400 x 400 mm
- Load Cell constructed from high strength aluminium alloy
- Approved to OIML R60 up to 6000d
- Sealed to IP 66 using a special silicon coating
- Optional ATEX II 2G EEx ia IIC T4 approval available
|
|
|

|
Load Cell 1130
Capacities: 7, 10, 15, 20, 30, 50, 75 and 100 kg
|
- Available in capacities from 7 - 100 kg
- Suitable for platform sizes up to 400 x 400 mm
- Stainless steel construction
- Load Cell is approved to OIML R60 up to 6000d
- For high accuracy weighing in harsh industrial environments
- Optional ATEX II 2G EEx ia IIC T4 approval available
- Sealed to IP 66 using a special silicone coating
|
|
|

|
Load Cell 1142
Capacities: 10, 15, 20, 30, 50, 75, 100 and 150 kg
|
- Available in capacities from 10 - 150 kg
- Suitable for platform sizes up to 400 x 400 mm
- Stainless steel construction
- Load Cell approved to OIML R60 up to 3000d
- For accurate weighing in harsh industrial environments
- Optional ATEX II 2G EEx ia IIC T4 approval available
- Sealed to IP 66 using a special silicone coating
|
|
|

|
Load Cell 1242
Capacities: 50, 100, 150, 200, 250 kg
|
- Load Cell Capacities from 50 - 250 kg available
- Suitable for platform sizes up to 400 x 400 mm
- Constructed from a high-strength aluminium alloy
- Approved to OIML R60 up to 3000D
- Ideal for medium capacity Platform Scales
- Optional ATEX II 2G EEx ia IIC T4 approval available
- Sealed to IP 66 using a special silicon coating
|
|
|

|
Load Cell 1250
Capacities: 50, 75, 100,150, 200, 250, 300, 500, 635, 750, 1000 and 1500 kg
|
- Available in capacities from 50 - 1500 kg
- Suitable for platform sizes up to 600 x 600 mm
- Constructed from a high strength aluminium alloy
- Approved to OIML R60 up to 3000D
- Optional ATEX II 1GD EEx ia IIC T6 approval available
|
|
|

|
Load Cell 1260
Capacities: 30, 50, 75, 100, 150, 200, 250, 300, 500 and 635 kg
|
- Load Cell available in capacities from 30 - 635 kg
- Suitable for platform sizes up to 600 x 600 mm
- Constructed from a high-strength aluminium alloy
- Approved to OIML R60 up to 3000D
- Ideal for medium to high capacity Platform Scales
- Optional ATEX II 2G EEx ia IIC T4 approval available
- Sealed to IP 66 using a special silicon coating
|
|
|

|
Load Cell 1320
Capacities: 1000, 1500 and 2000 kg
|
- Available in capacities from 1000 - 2000 kg
- Front mounting
- Suitable for platform sizes up to 1200 x 1200 mm
- Constructed from a high-strength aluminium alloy
- Load Cell is approved to OIML R60 up to 3000D
- Ideal for large high capacity scales and platforms
- Optional ATEX II 2G EEx ia IIC T4 approval available
|
|
|

|
Load Cell 1510
Capacities: 100, 250, 500 kg
|
- Load Cell available in capacities from 100 - 500 kg
- Suitable for platform sizes up to 600 x 600 mm
- Stainless steel construction
- Approved to OIML R60 up to 4000d
- Load Cell is Ideal for hostile environments
- Optional ATEX II 1GD EEx ia IIC T6 approval available
- Hermetically sealed to IP 68 by welding
|
|
|

|
Load Cell 240
Capacities: 2, 5, 7, 10, 15, 20, 30 and 50 kg
|
- Oil Damped Load Cell
- Available in capacities from 2 - 50 kg
- Suitable for platform sizes up to 400 x 400 mm
- Painted Steel or Stainless Steel housings available
- Load Cell with integrated internal overload device for
both over and under loads
- Ideal for dynamic applications such as filling and packaging machines
|
|
|
|
|

|
Load Cell 355
Capacities: 5, 10, 20, 30, 50, 100, 200, 250 and 500 kg
|
- Load Cell is pproved to OIML R60 up to 4000D
- Stainless steel construction
- Available in capacities from 5 kg to 500 kg
- Output at Rated Load trimmed to 2mV/V ± 0.1%
- Current matched versions available
- Load Cell is ideal for platform and floor scales
- Optional ATEX II 1GD EEx ia IIC T6 Approval available
- Hermetically Sealed to IP68 by welding
- A wide range of suitable mounting arrangements available
|
|
|

|
Load Cell 3410
Capacities: 250, 500, 1000 and 2000 kg
|
- Approved to OIML R60 up to 3000D
- Alloy Steel construction.
- Available in capacities from 250 kg to 2000 kg
- Ideal for floor scales, silo and hopper weighing
- Optional ATEX II 1GD EEx ia IIC T6 Approval available
- Load Cell sealed to IP67 by potting
- A wide range of suitable mounting arrangements available
|
|
|

|
Load Cell 3510
Capacities: 300, 500, 750, 1000, 1200, 2000, and 5000 kg
|
- Load Cell is approved to OIML R60 up to 6000D
- Stainless Steel construction
- Available in capacities from 300 kg to 5000 kg
- Ideal for floor scales, silo and hopper weighing
- Optional ATEX II 1GD EEx ia IIC T6 Approval available
- Sealed to IP68 by welding
- Load Cell fitted with a 6 wire double shielded cable
- A wide range of suitable mounting arrangements available
|
|
|
|
|

|
Load Cell Mounting SF-3510T
|
- Complete mounting accessory for the load cell 3410/3510
- Fixed height rubber foot with domed load adaptor
- Robust and corrosion free stainless steel
- Ideal for platform, container and floor scales
- Provides precise axial and torque free loading
- Acid resistant Neoprene material with a high Shore hardness
|
|
|

|
Load Cell Mounting SF-3510T-HA
|
- Complete mounting accessory for the load cell 3410/3510
- Height adjustable rubber foot with domed load adaptor
- Robust and corrosion free stainless steel
- Ideal for platform, container and floor scales
- Provides precise axial and torque free loading
- Acid resistant Neoprene material with a high Shore hardness
|
|
|

|
Load Cell Mounting SFM-3510T
|
- Complete mounting accessory for the load cell 3410/3510
- Flanged rubber foot with domed load adaptor
- Robust and corrosion free stainless steel
- Ideal for platform, container and floor scales
- Provides precise axial and torque free loading
- Acid resistant Neoprene material with a high Shore hardness
|
|
|

|
Load Cell Mounting CMX-3510
|
- Complete mounting arrangement for the 3510 load cell
- Ideal for Hopper and Silo weighing
- Robust, industrial stainless steel construction with mechanical lift off.
- Built-in jacking facility
- Heavy duty braid between to and bottom plates
- Complete with screws and cable protection
|
|
|

|
Load Cell Mounting CMX-355
|
- Complete mounting arrangement for the 355 load cell
- Ideal for Hopper and Silo weighing
- Robust, industrial stainless steel construction with mechanical lift off.
- Built-in jacking facility
- Heavy duty braid between top and bottom plates
- Complete with screws and cable protection
|
|
|

|
Load Cell Mounting BC-355
|
- Complete mounting arrangement for the 355 load cell
- Ideal for platforms, hopper and conveyor scales
- High self centering forces for better repeatability
- Can be purchase as a complete kit
- Ball & cup, base kit and cable protector kit available separately
|
|
|

|
Load Cell Mounting KPE-355
|
- Mounting Accessory:
Ball and Cup Modules
|
|
|

|
Load Cell Mounting BK-355
|
- Mounting Accessory:
Separate Base Kit (Plated Alloy Steel)
|
|
|

|
Load Cell Mounting UPS
|
- Mounting Accessory:
Cable Protector, Spacer and Bolts
|
|
|

|
Load Cell Mounting SF-355
|
- Self aligning foot for the model 355 load cell
- Available for load cell capacities from 5 kg up to 250 kg
- Stainless steel construction
- Excellent load introduction
- Low profile
- Ideal for constructing low capacity platform scales
- Easy installation
- Can be used with optional base kit BK-355
|
|
|

|
Load Cell Mounting SHKM-355
|
- Mounting accessory for the 355 load cell
- Available for capacities from 5 kg up to 250 kg
- ideal for dealing with shock loads and vibration
- Provides essential centering forces
- Available separately (SHKM-355) or with optional base kit (BK-355)
|
|
|

|
Load Cell Mounting ZV-355
|
- Complete mounting arrangement for the 355 load cell
- Available for load cell capacities from 5 kg up to 250 kg
- Self aligning rod end bearings
- Stainless steel construction
- Ideal for low capacity high accuracy applications
- Easy installation and removal of the load cell
|
|
|

|
Load Cell Mounting SM-220R
|
- Complete mounting arrangement for the 220 load cell
- Available for capacities from 5 to 30 T
- Robust, Industrial steel construction
- Built in lift off protection
- Integrated jacking facility
- Can tolerate load misalignment up to ± 3 ° from vertical
- Alloy steel and Stainless steel options.
|
|
|

|
Load Cell Mounting PLH1
|
- Self aligning module with excellent load introduction
- Complete Installation for the SM63 load cell
- Available for load cell capacities from 7.5 tonnes to 300 tonnes
- Ideal for the silo, tank and truck scales
- Manufactured from high quality tool steel,
- Integrated lift off and bumper stops.
- Easy assembly, ideal for large silos & tanks
|
|
|
|
|

|
Load Cell 614
Capacities: 50, 100, 150, 200, 300, 500 kg
|
- Available in capacities from 50 kg to 500 kg.
- Can be used in tension or compression
- Constructed from a high strength aluminium alloy
- Approved to OIML R60 3000D
- Ideal for all hanging scales
- Sealed to IP 67 by potting
- Fitted with a 6 wire double shielded cable
- Optional ATEX II 2G EEx ia IIC T4 Approval available
|
|
|

|
Load Cell 615
Capacities: 50, 100, 150, 200, 300, 500, 750, 1000 kg
|
- Available in capacities from 50 kg to 1000 kg.
- Can be used in tension or compression
- Constructed from a high strength alloy steel
- Output at Rated Load trimmed to 2.0 mV/V ± 0.1%
- Ideal for all hanging scales
- Sealed to IP 67 by potting
- Fitted with a 6 wire double shielded cable
- Optional ATEX II 2G EEx ia IIC T4 Approval available
|
|
|

|
Load Cell 616
Capacities: 50, 100, 150, 200, 300, 500, 750, 1000 kg
|
- Available in capacities from 50 kg to 1000 kg.
- Can be used in tension or compression
- Constructed from a high strength stainless steel
- Output at Rated Load trimmed to 2.0 mV/V ± 0.1%
- Ideal for all hanging scales
- Sealed to IP 67 by potting
- Fitted with a 6 wire double shielded cable
- Optional ATEX II 2G EEx ia IIC T4 Approval available
|
|
|

|
Load Cell 619
Capacities: 1500, 2000, 3000 and 5000 kg
|
- Available in capacities from 1500 kg to 5000 kg.
- Can be used in tension or compression
- Constructed from a high strength alloy steel
- Output at Rated Load trimmed to 2.0 mV/V ± 0.1%
- Ideal for all hanging scales
- Sealed to IP 67 by potting
- Fitted with a 6 wire double shielded cable
- Optional ATEX II 2G EEx ia IIC T4 Approval available
|
|
|

|
Load Cell 620
Capacities: 500, 1000, 2000 and 5000 kg
|
- Available in capacities from 500 kg to 5000 kg.
- Can be used in tension or compression
- Constructed from a high strength alloy steel
- Output at Rated Load trimmed to 2.0 mV/V ± 0.1%
- Ideal for all hanging scales
- Sealed to IP 68 by welding
- Fitted with a 6 wire double shielded cable
- Optional ATEX II 1GD EEx ia IIC T6 Approval available
|
|
|
|
|

|
Load Cell 220
Capacities: 5, 10, 20, 30, 50 t
|
- Approved to OIML R60 up to 6000D
- Output trimmed to 2mV/V ± 0.1%
- Available in capacities from 5000 to 50000 kg
- Ideal for car, silo and tank weighing
- Optional ATEX II 1 GD EEx ia IIC T6 approval available
- Hermetically sealed to IP68 by welding
- A wide range of suitable mounting arrangements available
|
|
|

|
Load Cell SM63
Capacities: 7.5, 15, 22.5, 30, 40, 50, 100, 150 and 300 t
|
- Approved to OIML R60 4000D
- Available in capacities from 7.5 tons to 300 tons
- ideal for the silo, tank and truck scales
- Optional ATEX II 1GD EEx ia IIC T6 available
- Hermetically sealed to IP68 by welding
- Current matched to prevent corner errors
- Suitable mounting arrangements available
|
|
|
|
|

|
Weighing Indicator NPR
|
- Approved to OIML R76 for 4000d
- RS232 and RS422 interface for PC / PLC & Printers
- Rugged aluminium housing with screw terminals
- Optional analogue output 0/4..20mA 16 bit resolution
- 2 setpoints with solid state relay outputs
- 6 opto-isolated logic inputs for remote key operation
- Cost effective Industrial Indicator
|
|
|

|
Battery Powered Weighing Indicator MW-LE
|
- Approved to OIML R76 for 4000d
- RS-232 and RS-422 interface for PC / PLC & Printers
- 50 samples per second, 0.005% Linearity
- Ideal for all mobile weighing applications 12/24 V DC
- 5 logic inputs and 2 open-collector logic outputs
- Piece counting and pre-set tare functions
- Rugged aluminium housing with screw terminals connections
|
|
|

|
Weighing Indicator QMA
|
- Approved to OIML R76 for 10,000d
- RS232 and RS422 interface for PC / PLC & Printer
- 1000 samples per second, 0.0015% Linearity
- 4 setpoints with solid state relay outputs
- 8 opto-isolated logic inputs for remote key operation
- Optional Profibus DP interface
- Optional analogue output 0 .. 10V or 0/4...20mA
|
|
|

|
Strain Gauge Transducer Indicator FMD
|
- Ideal for all force and torque applications
- Peak, Track, Min/Max and Hold mode available
- RS232 or RS422 interface for connection to PC or PLC
- 250 samples per second, 0.005% Linearity
- Analogue output 0/4..20mA or 0 ..10 V
- 2 Setpoints with solid state relay outputs
- 4 optically isolated inputs for remote keyboard operation
|
|
|

|
Filling Controller & Indicator SAI-MV
|
- Approved to 4000d NMI, 250 samples/sec 16 bit ADC
- Ideal for filling and dosing applications
- 2 solid state relay outputs for coarse and fine filling
- In-flight correction, automatic or manual
- Gross or net filling (auto tare on Start filling)
- 5 logic inputs which includes Start and Stop filling
- RS232 interface with ASCII protocol for PC communication
- Optional RS422 interface for multi-drop bus
- Robust panel mounted aluminum housing
|
|
|

|
Checkweighing Indicator SAI-CK
|
- Designed for use with in-line checkweigher
- 250 samples per second
- Approved by NMI to 4000d :Certificate TC2636
- Too high, too low and pass judgements in milliseconds
- Solid state relay outputs for too high and too low
- Photocell input for Start weighing sequence
- RS232 interface with optional print facility
- LED display with bargraph
- Panel mounted aluminium housing
|
|
|

|
Weighing Indicator Mi4000
|
- Fully programmable via keypad and comms port
- Password protected, keypad disable
- Auto calibration and auto tare
- 4.5 digit high resolution
- Gross, Tare and Net functions
- Optional RS 232, RS 485 or current loop interfaces
- Optional analogue output with voltage or current
- Optional up to 16 relay setpoints
- Panel or DIN rail mounting
|
|
|

|
Weighing Indicator Mini-Mate
|
- An ideal combination of a weighing and control system:
- Simple programming of the dosing sequence via a PC
- Even complex control programs can be written in a few hours using a combination of the 50 proven software modules available
- complete control program typically consists of 15 process
steps and requires no more than 1 hours work
- 8 Input / 8 Outputs or 8 Inputs, 4 Output & Analogue output option; Optional Profibus DP interface available
|
|
|

|
Programmable Weighing Controller SMART
|
- Approved to OIML R76 for 10,000d
- RS232 and RS422 interfaces for PC / PLC & Printer
- 1000 samples per second, 0.0015% linearity
- Freely programmable using intelligent programming software
- 8 optically isolated inputs and 8 outputs
- Optional Profibus DP interface
- Optional analogue output 0 .. 10V or 0/4...20mA
|
|
|
|
|

|
Strain Gauge Amplifier LAU 63.1
|
- Ideal for Force measurement applications
- Output 0- ±10V DC
- Linearity better than 0.010% of full scale
- Designed to drive 1 off 350-2K Ohm Load Cell
- Zero offset ±0.7 mV/V in 0.1 mV/V steps
- Relative Gain Settings between x1 and x7
- Selectable low pass filter 3.3 Hz to 3300 Hz
- Shielded PCB construction
|
|
|

|
Strain Gauge Amplifier LAU 73.1
|
- Output 0-20mA or 4-20mA or 0-10V (with resistor)
- Linearity better than 0.010% of full scale
- Input signal range -0.2mV/V to +2.3 mV/V
- Zero offset 0-65% (1.5mV/V) of full scale
- Selectable gain allowing signals as low as 0.25mV/V to be amplified to 20mA
- Selectable low pass filters between 0.33Hz and 33Hz
- Shielded PCB construction with simple connectors
|
|
|

|
Universal Load Cell Amplifier LAC 65.1
|
- Linearity better than 0.010 % of full scale
- Analogue Output 0/4-20mA and 0-±10V DC
- Capable of driving 8 off 350 Ohm load cells
- Active low pass filter from 0.25 Hz to 32 Hz
- Zero offset up to ±80% of full scale
- Input signal range up to ±3.3mV/V
- Zero and Span coarse and fine adjustment
- Steel case mounted on Phoenix DIN rail module
|
|
|

|
Load Cell Amplifier LAC 74.1
|
- Linearity better than 0.010% of full scale
- Analogue outputs of 0/4..20mA or 0 -10V DC
- Active low pass filter from 0.33Hz to 33Hz
- Zero offset up to ±90% of full scale
- Input signal range up to 3.5 mV/V
- Zero and Span coarse and fine adjustments
- PCB with plated steel case mounted on DIN rail clips
|
|
|

|
Load Cell Amplifier LAB 101.1
|
- Precision strain gauge amplifier using a 4-20mA passive output
- 2 wire technology for cable lengths up to 1000 m
- Compact aluminium housing, only 16 mm high
- Industrial specification EMC protection, 30 V/m EMI tested
- Sealed to IP 65 using metal PG type glands
- Fine adjustment of both zero and gain
|
|
|

|
Load Cell Amplifier LAB 104.1
|
- 10V DC output which is short circuit protected
- All strain gauge transducer with input impedance between 250 and 2000 Ohms can be connected
- Compact, highly accurate, inexpensive amplifier
- Aluminium housing with 2 metal PG glands
- Amplifier supply voltage 14 to 28 V DC
- Active low pass filter from 3.3 Hz to 33 Hz
|
|
|
|
|

|
Load Cell Amplifier DAS 72.1
|
- Can be calibrated directly from load cell mV/V sensitivity
- 2400 internal conversions/second ± 18 bit resolution
- Linearity better than 0.002% signal resolution ~50nV
- Designed to drive four 350 Ohm Load Cell
- ± 3.2mV/V input maximum.
- Digital display maximum -99,999 to +99,999 counts
- Analogue output 0-20mA
- RS-422/RS-485, 2 or 4 wire Computer Interface
- 3 Optically Isolated Logic Inputs
- 3 Optically Isolated Open Collector Logic outputs
|
|
|

|
Load Cell Amplifier LDU 68.1
|
- Approved to OIML R76 10,00d 1uV/d, CE certified
- Bipolar input range for weight, force or torque applications
- 80 samples/second at greater than 16 bit resolution
- Linearity better than 0.005 %, Signal resolution ~50 nV
- Maximum read out ± 99,999 count
- RS-422/RS-485, 2 or 4 wire Computer Interface
- 2 logic inputs and 2 logic outputs.
|
|
|

|
High Precision Load Cell Amplifier LDU 69.1
|
- Approved to OIML R76 10,000d, 0.1uV = 1dLinearity better than 0.002 %, signal resolution ~ 20 nV
- Extremely low temperature drift typically 1ppm/°C
- Bipolar input range for weight, force or torque applications
- Up to 172 readings per second transmitted
- RS-422 / RS-485 2 or 4 wire Computer Interface
- Full computer control and set-up via the computer interface
- Full wrap around steel case for better EMC performance
|
|
|

|
Fast Load Cell Amplifier LDU 78.1
|
- OIML approved R76 5000D 0.7uV per divison
- Linearity better than 0.002 %, signal resolution ~ 100 nV
- 2400 internal samples per second
- RS-422 / RS-485 2 or 4 wire Computer Interface
- 2 logic inputs & 2 logic outputs
- Full computer control and set-up via the computer interface
- Easy, logical command protocol and syntax
- Full wrap around steel case for better EMC performance
|
|
|

|
Strain Gauge Amplifier SGM 450
|
- All weight indicator functions available
- Load cell excitation 10V DC to 1KHz AC with sense
- Will drive up to 6 Load Cells, 350 Ohm
- 50 conversions per second / 24 bit internal resolution
- Output RS 232 or RS 422
- Up to 32 devices on one bus (RS 422)
- Fully software controlled
- Communication via ASCII commands
|
|
|

|
Strain Gauge Amplifier SGM 500
|
- All weight indicator functions available
- Load Cell excitation 10V DC, with sense
- Will drive up to 4 Load Cells, 350 ohm
- 1000 conversions / second
- 16 bit internal resolution
- Output RS232 or RS 422, opto isolated
- Fully software controlled
- Communication via ASCII commands
|
|
|
 |
|
|
|

|
Load Cell Simulator LCS-3
|
- High quality load cell simulator with 0.03% accuracy
- In 0.5 mV/V steps from 0 to ± 3 mV/V, continuously variable ± 2mV/V
- Compact pocket size, ideal for service applications
- Input and output impedance 350 Ohm ± 1 Ohm
- Selectable polarity for symmetry tests
- Standardized Dimensions L70 x W29 x H172 mm
|
|
|

|
Load Cell Junction Box QLJ
|
- High quality junction box for up to 4 load cells
- Robust PCB with screw and solder terminals
- Industrial standard aluminium housing
- Cable entries via metal glands
- Sealed to IP 65
- Standard dimensions W175 x H80 x D57 mm
|
|
|

|
Converter USB to RS485/422
|
- Isolated RS485/422 interface
- UK designed and manufactured
- Baud rates up to 1 Mbps
- RS485 half duplex link selectable
- Selectable 120 Ohm termination resistor
- Powered from the USB port
|
|
|

|
Stainless Steel Load Cell Junction Box AJB04-S
|
- Connect up to 4 load cells into one output
- Stainless steel enclosure
- Five stainless steel PG 9 glands
- Sealed to IP67
- Screw terminal connectors for inputs and outputs
- Integrated surge protection
- Easy corner trimming using built-in potentiometers
- Also available for 6, 8, & 10 load cell inputs
|
|
|

|
ATEX Load Cell Junction Box KAEX
|
- Connect up to four load cells into one output
- Aluminium enclosure with earth connection
- Four M16 (Inputs) and one M20 (Output) glands
- Sealed to IP66
- Cascade boxes together for more than 4 load cells
- Screw terminal connectors for inputs and outputs
- ATEX approved EEX ia II C T6
- Add optional resistors for corner error correction
|
|
|

|
Beka Text Display BA688C
|
- Remote serial text display to be used with DAS72.1
- Connects directly to DAS72.1 Communication port
- Internal script requests information from DAS72.1
- Display shows Gross / Net weight & No motion
- Push buttons to set a new zero or tare
- Supply voltage 20 - 36 VDC
- RS 485 2 wire Computer Interface
- Can be used with Wireless Links
|
|
|

|
Beka Text Display BA488C (ATEX Option)
|
- Remote serial text display to be used with DAS72.1
- Can be mounted in the Hazardous area
- Connects to DAS72.1 RS485 port via an comms Isolator
- Internal script requests information from DAS72.1
- Display shows Gross / Net weight & No motion
- Push buttons to set a new zero or tare
- Supply voltage 20 - 36 VDC
- RS 485 2 wire Computer Interface
- Can be used with Wireless Links
|
|
|

|
Safety Barriers for ATEX Applications
|
- For use with load cells working in Hazardous Areas
- Designed to live in the Safe Area
- Limits energy available in the Hazardous Area
- Plug in screw terminal connections
- Din rail clip mounting
- Short circuit protected Zener Barrier
- Compact space saving construction
|
|
|
|